Sale!

RESJOY VentMed™ BiPAP Machine VM7

$849.00

The VentMed BiPAP VM7 is an automatic bi-level device that delivers effective therapy for a wide range of users noncompliant with traditional CPAP devices. It delivers two different values of air pressure, one for inhaling, another for exhaling, to hold a user’s upper airway open and help him/her breathe more effectively. The VentMed VM7 is a premium BiPAP for patients who have been diagnosed with severe sleep apnea.

resjoy ventmed bipap machine sleep apnea machine vm7
RESJOY VentMed™ BiPAP Machine VM7 $1,040.00 $849.00

Fast shipping worldwide, door to door delivery.

  • PayPal & Credit Cards Secure Checkout.
  • Processing time 1-2 days; Global Express Shipping 4-6 days.
Guaranteed Safe Checkout

VENTMED VM7 BIPAP
Play Video about VENTMED VM7 BIPAP

* VM 7 & VM8 have the same video

VentMed BiPAP VM7

The VM7 BiPAP machine comes with a host of comfort features, including Ti-control, easy breathe technology, a heated humidification system, and EPR(expiratory pressure relief).

 It comes with large shuttle buttons and an intuitively designed screen capable of letting you know everything from therapy to data to the quality of your mask seal. 

Ideal for OSA

Ideal for treating patients with sleep apnea and respiratory insufficiency, like OSA (Obstructive Sleep Apnea), CSA (Central Sleep Apnea), COPD, OHS etc.

Heated Humidifier

To help you sleep soundly and wake up refreshed, the heated humidifier is designed to add consistent humidification to your pressure air, making it easier to stick with your sleep therapy.

Comfort Sleep Therapy

Auto S, ST mode, Smart Ramp, Expiratory relief, Heated Humidification system help to make your therapy comfortable and allows you to sleep undisturbed.

High Pressure Level

Range of 4-25 cm H20. The elevated pressure capabilities are ideal for users with severe forms of sleep apnea, who generally require a high-pressure setting.

How Can A VM7 BIPAP Help You?

Don’t risk your life if you have a serious condition that affects your lungs. The most severe conditions require the best treatments. The VentMed BiPAP Machine VM7 is a highly reliable machine that can treat the following conditions.

Advance Event Detection

Built in device intelligence so that you can make the most informed decisions possible. VentMed BPAP Machine VM7 can identify and analyze different types of respiratory events that help you determine appropriate clinical management of obstructive sleep apnea (OSA).

All events can now be verified by looking at detailed user flow waveform data captured by the device.

 

Monitored Respiratory Events

  • OAI (Obstructive Apnea Index)
  • AHI (Apnea–Hypopnea Index)
  • PB (Periodic Breathing)
  • FL (Flow Limitation)
  • CAI (Central Apnea Index)
  • HI (Hypopnea Index)
  • SNI (Snore Index)
  • RERA (Respiratory Effort Related Arousal)
resjoy ventmed bipap

Superior Tech. Superior Features

EPR mode

Expiratory Pressure Relief

The VM7 BIAP automatically sets EPR (Expiratory Pressure Relief) function so you may find it easier to breathe out. This can help you get used to therapy.

You can set the expiratory pressure relief Level to off (0) or between 1 and 3, where 1 is the lowest expiratory pressure relief and 3 is the highest setting.

Heated Humidifier

The humidifier moistens the air and is designed to make therapy more comfortable. You can set the Humidity Level to off (0) or between 1 and 5, where 1 is the lowest humidity setting and 5 is the highest humidity setting.

The push-pull water tank design is very easy to disassemble and install, which is convenient for adding water and cleaning.

heated humidifier
AUTO ST

ST Mode & Backup Rate (BUR)

A BPM value (Breaths per Minute) can be set as a backup rate in ST Mode. If the user’s spontaneous respiratory rate falls below that value, the device will add pressure to prompt him/her to breathe.

With the machine intervening in the breathing, it can help the user inhale and exhale more easily during challenging conditions, lowering respiratory muscle workload. It can also get the user more oxygen and reduce CO2 in the user’s bloodstream.

VM7 BiPAP - More Features To Know

Auto ON / OFF

Designed to make the device start automatically in a while after you wear mask, and stop the device work automatically in 10 seconds after you take mask away.

The Auto ON/OFF function can be turned off on the menu.

Smart Ramp Settings

It lets the sleep apnea therapy start from a low and pleasant pressure level when the user is still awake. Then the air pressure is gradually ramped up to the correct level and the user can easily fall asleep without even noticing the increment.

Sleep Tracking

It comes with a TF card that will allow you to keep detailed data about your sleep disorder. The new TF card will allow you to store your sleep apnea information, which will enable you to get therapy support from your doctor, and compile compliance reports.

Alarm Setting

Designed to alarm when there is leakage. Can set as ON or OFF.

Whisper-Quiet

It is less than 26 decibels (dB), making it quieter than a whisper and comparable to leaves rustling.

FAQs

Product Name
BIPAP VM-7
Material
ABS+plastic
Color
Black
Work mode
CPAP,Auto,Auto S, S,T,ST
Sound
<28db
Data storage
TF card
Screen
2.8 inch color
Pressure Range
4-25cmH2O 
Power supply
Input100-240V.50-60Hz,1-2A; Output+24V,2.5V
Over-temperature protection
Stop working automatically,
buzzle ring 4 times
Ramp item 
0-60min adjustable  1 min/step
Auto ON/OFF
Yes
EPR
Yes,0-3 level
Auto-Altitude
Yes
Leak compensation
Yes
Awake detection
Yes
Breath Event detection
Yes
Auto pressure titration
Yes
Water Capacity
200ML max
Humidifier
Heated Humidifier,0-5 level
Mask /power Off Alarm
Yes
Dimensions
29L*15W*10H(machine);
38.5L*36.5W*16H(carton)
Weight(With humidifier)
1.8KG(Net weight);4KG(Gross weight)
work for
OSA /CSA /MSA/ Hypopnea/ COPD

VM-7 BiPAP mahcine with integrated heated humidifier, water tank, power lead, travel bag, english user manual, 5*air filter, TF Card, face mask( VM7 comes with face mask by default; we can replace nasal mask according to  your requirement. Besides, the default mask size is M, and please just remark it if you want size L.)

You will know that therapy is on when the air fan icon is rotated. The current treatment pressure is shown in white words. 

During ramp time the pressure is gradually increasing and you will see a blue triangle icon on the screen once the prescribed pressure is reached.

The screen will go black automatically after a short period of time. You can press any button to turn it back on.

The device has many high-sensitivity sensors, and it alarms with ‘beeping’ sound when it detects air-leakage. Please inspect the mask and tube carefully to make sure they are fitted correctly and not leaking. You can read air-leakage data on the screen, if data is over 30, it means the air-leakage is occurring.

Yes sure. The device has two therapy modes – CPAP and Auo CPAP / APAP.

In work mode CPAP, press shuttle button to highlight Pressure. Rotate shuttle button to adjust working pressure. You can set pressure 4-20 cmH2O for CPAP mode.

Clean the device weekly as described. Refer to the mask user guide for detailed instructions on cleaning your mask.

  1. Wash the water tank and air tubing in warm water using mild detergent. Or sanitize them by using a CPAP cleaner & sanitizer. Do not wash in a dishwasher or washing machine.
  1. Rinse the water tank and air tubing thoroughly and allow to dry out of direct sunlight and/or heat.
  1. Wipe the exterior of the device with a dry cloth.

You can take this device with you wherever you go. Just keep the following in mind:

  • Empty the water tank and put it into the device.
  • Use the travel bag provided to prevent damage to the device.
  • Do not use the device with water in the water tank on a plane due to the risk of inhalation of water during turbulence.

(it feels like getting too much air

If you are feeling too much air at the beginning of therapy, the Ramp may be turned off. You can turn on the Ramp time and the pressure will increase gradually at a pleased speed.

It feels like I am not getting enough air. Ramp may be in progress. Just wait for air pressure to build up or turn Ramp Time off.